How to remove Er-49 on DA98C Servo Driver?
Follow this video:
Press the DA98C AC Servo Driver fourth key twice, then press the first key once, and finally press the last key twice.
Change the value from 315 to 535, then press the first key once.
Press the last key twice again, then press Return twice.
Use the second key to find “ab-”, then press Enter twice.
When the “FINISH” message appears, power off the machine completely and restart it. The alarm should then be cleared.
This method is intended for situations where an alarm cannot be cleared after replacing the battery. The issue is resolved by adjusting the parameter and performing a restart procedure.
Press the DA98C AC Servo Driver fourth key twice, then press the first key once, and finally press the last key twice.
Change the value from 315 to 535, then press the first key once.
Press the last key twice again, then press Return twice.
Use the second key to find “ab-”, then press Enter twice.
When the “FINISH” message appears, power off the machine completely and restart it. The alarm should then be cleared.
This method is intended for situations where an alarm cannot be cleared after replacing the battery. The issue is resolved by adjusting the parameter and performing a restart procedure.