FANUC System APC Alarm – Absolute Pulse Coder (APC) Alarm
Causes of the Alarm:
-
The battery is depleted, the encoder cable is shorted, open-circuited, or has been disconnected, or the axis disassembly signal is abnormal, etc.
-
Alarm codes 300 to 349 correspond to APC (Absolute Pulse Coder) alarms. You can refer to the specific alarm number and on-screen message for detailed information, as shown in the image.
-
After the fault is resolved, set the mechanical zero point:
-
Locate the mechanical zero point.
-
In parameter 1815 — APC, set APZ = 1.
-
(If the battery is replaced without powering off, the zero-point reset can be avoided.)
-
Common APC-Related Alarm Cases and Troubleshooting
SV0301 – APC Alarm: Communication Error
-
Check the feedback cable for poor contact; replace the cable if needed.
-
Inspect the servo drive control PCB; replace if necessary.
-
Replace the pulse coder.
SV0306 – APC Alarm: Overflow Alarm
-
Check that parameters No.2084 and No.2085 are correctly set.
-
Replace the pulse coder.
SV0307 – APC Alarm: Excess Axis Movement
-
Check whether the feedback cable is normal.
-
Replace the cable if needed.
SV0360 – Pulse Coder Code Check Error (Built-in)
-
Inspect the pulse coder for faults.
-
Replace the pulse coder.
SV0364 – Software Phase Alarm (Built-in)
-
Check the pulse coder.
-
Replace the pulse coder.
-
Check for electrical noise and ensure the feedback cable shielding is intact.
SV0366 – Pulse Loss Alarm (Built-in)
-
Check shielding of the feedback cable; ensure there’s no interference.
-
Replace the pulse coder.
SV0367 – Count Loss Alarm (Built-in)
-
Verify feedback cable shielding and check for interference.
-
Replace the pulse coder.
SV0368 – Serial Data Error (Built-in)
-
Ensure proper feedback cable shielding.
-
Replace the cable.
-
Replace the pulse coder.
SV0369 – Serial Data Transmission Error (Built-in)
-
Check feedback cable shielding and look for interference sources.
-
Replace the cable.
-
Replace the pulse coder.
SV0380 – Separate Detector LED Abnormal (External)
-
Check whether the separated interface unit (SDU) powers on correctly.
-
Replace the SDU if necessary.
SV0385 – Serial Data Error (External)
-
Check if the SDU is functioning correctly.
-
Inspect the feedback cable between the encoder scale and the SDU.
-
Check the encoder scale itself.
SV0386 – Data Transmission Error (External)
-
Verify the SDU is operating correctly.
-
Inspect the feedback cable between the encoder scale and SDU.
-
Check the encoder scale.