AC servo driver Err13 alarm
Paycnc.com - PAY for CNC components
AC servo driver Err13 alarm
AC servo driver alarms Err13 means it is overloaded.
 
Causes:
  1.       One of the U, V or W open circuit.
  2.       AC servo driver is not matched with the AC servo motor.
  3.       The torque of the AC servo motor is not big enough.
  4.       AC servo driver is broken.
 
Solutions:
  1.       Check the cables.
  2.       No.1 parameter of the AC servo driver is match with the AC servo driver or not? If not please set it right then recovery the default parameters.
  3.       Check machine load, is it too heavy?
  4.       Reduce the start and stop frequency, or increase the acceleration-deceleration time constant.
  5.       Replace a bigger AC servo motor & driver.
  6.       Send back the AC servo driver to repair.
TOP
Message Us